One of the great tools in the ICU, the Bestman feeding pump

   2020-06-09

Bestman showed you intensive care unit (ICU) in his article. He listed many medical devices in ICU ward, such as ECG monitor, blood filter, ventilator, ECMO, etc. The role of various medical devices is an eye-opener for us. It is really "the next door to the road to death".

In addition to these medical devices for heart, blood and respiration, there are other important devices in ICU, such as feeding pump, also known as enteral nutrition pump.

Not long ago, news media reported that a 4-year-old boy in Kent, England, had a soft and reflux voice when he was born, so he could not eat properly. He survived by using a feeding pump connected to his stomach. But the feeding pump can only keep him alive. His body is much smaller than that of his peers. However, as he grows older, his illness will endanger his life.

Like other medical devices in the intensive care unit, when other treatments fail, the blood supply pump can become the hope of the critically ill patients.

Patients who need enteral nutrition support should use a feeding pump to assist feeding during nutrition support. The advantages of Besman feed pump are as follows:

1. The infusion speed and volume can be accurately controlled;

2. Avoid gastrointestinal complications caused by rapid perfusion;

3. Reduce the injury and stimulation of the pipeline to the patient.

 

The use of Bess feed pump can ensure stable nutrient solution concentration, temperature, speed and osmotic pressure, reduce diarrhea, reflux, aspiration pneumonia, gastric tube obstruction and other complications, ensure effective implementation of enteral nutrition, improve the work efficiency of medical staff and the cure rate of severe patients. At the same time, the feed pump has the advantages of small size, high safety, economy, convenient operation, and broad clinical application prospects in the future.

 

Besman feeding pump is used for enteral feeding of patients (patients). The enteral nutrition liquid fed by the human body can provide additional power, and can control the enteral nutrition liquid to flow into the stomach and intestines of the human body at a directional and constant speed in the infusion tube, which is conducive to the absorption and utilization of enteral nutrition liquid and is popular with patients.

 

The parameters of Besman feed pump are as follows:

1. Microcomputer control, accurate and reliable; Automatic alarm device, safe and reliable; Step by step touch the buttons on the panel

2. The pump pipe can be quickly connected with bottles and bags

3. Real-time memory function ensures the personalization and accuracy of infusion dose and speed

4. Multiple sensor technologies can detect upstream and downstream flow status

5. Automatic filling function

6. AC/DC dual power supply 

7. Unique bottom suction cup design prevents overturning caused by touch during operation and placement

8. Preheating function of nutrient solution (optional)

9. Flow setting range: 50-400ml/hr Increment: 1ml/hr

10. Flow rate accuracy: 10% of the selected flow rate or 0.5ml/hr, whichever is greater

11. The total infusion volume of continuous feeding is 50-3000mL, and the total infusion volume of intermittent feeding is 50-1000ml, with an interval of 1-100 times and an interval of 1-24h. Rinse 10-500ml of solution at 1-24h intervals.